| Method | Decompression-chamber wall heating |
| Operating temp, range | 40-200°C |
| Operating vacuum range | 101-0.1kPa (760-1Torr) |
| Temp, adjustment accuracy | ± 1.0°C (at 200°C) |
| Interior | Stainless steel plate |
| Exterior | Cold rolled steel plate with chemical proofing coating |
| Insulating material | Glassfiber |
| Heating method | Decompressed chamber wall direct heating |
| Heater power | 6.5kW |
| Observation window | Toughened glass + resin protection panel |
| Vacuum gauge | Pointer type, -100~0kPa |
| Vacuum pump installation room | Yes |
| Temp, control | 3 segments PID |
| Temp, setting | Use specialized function menu key and up/down key to set |
| Temp, display | Measured temp, display: green 4-digit LED digital display |
| Setting temp, display: red 4-digit LED digital display |
| Timer | 1min-99 hr 59 min and 100 hr-999 hr 50 min (attached with timing wait function) |
| Operation function | Fixed temp, auto start, auto stop, program operation |
| Program mode | Program operation 3 segments 30 steps (30 stepsx1, 15 stepsx2,10 stepsx3) |
| Additional function | Deviation correction, key lock, power outage compensation |
| Heater circuit control | SSR driving |
| Sensor | K thermocouple (temp, controller and overheat protector) |
| Safety device | Self-diagnosis circuit (abnormal temp, sensing, heater disconnection, auto overheat prevention, SSR short circuit), overheat protector, EBL to prevent overcurrent, key lock. etc. |
| Internal dimensions (WxDxHmm) | 800x800x800 |
| External dimensions (WxDxHmm] | 1020x1020x1850 |
| Internal capacity | 512L |
| Air exhaust port | NW40 flange |
| Air suction port | Rc 3/8 |
| Power source (50/60Hz) rated current | AC220V |
| Weight | ~450kg |
| Accessories | Stainless steel punching plates, 2 pcs. |