Measurement Ranges and Accuracy |
Voltage | - DC:
- 99.99 V, ±(0.7% + 2 digits)
- 999.9 V, ±(0.7% + 2 digits)
- AC:
- 0.05 to 99.99 V, ±(1% + 5 digits)
- 999.9 V, 50 to 500 Hz
|
VDF | - ACV:
- 0.05 to 99.99 V, 50 to 60 Hz ±(1% + 5 digits)
- 999.9 V, 50 to 60 Hz ±(1% + 5 digits)
- ACA:
- 0.1 to 99.99 A, 50 to 60 Hz ±(2% + 5 digits)
- 999.9 A, 50 to 60 Hz ±(2% + 5 digits)
|
Current | - DC:
- 99.99 A, ±(2% + 0.5 A)
- 999.9 A, ±(2% + 5 digits)
- AC:
- 0.10 to 99.99 A, 50 to 60 Hz ±(2% + 5 digits)
- 999.9 A, >60 to 400 Hz ±(2.5% + 5 digits)
|
Peak Hold | - ACV:
- 140 V, ±(3% + 15 digits)
- 1400 V, ±(3% + 15 digits)
- ACA:
- 140 A, ±(3.5% + 15 digits)
- 1400 A, ±(3.5% + 15 digits)
|
Frequency | - 20 to 99.99 Hz, ±(0.5% + 3 digits)
- 20 to 999.9 Hz, ±(0.5% + 3 digits)
- 0.02 to 9.999 kHz, ±(0.5% + 3 digits)
|
Total Harmonic Distortion ACA/ACV | 99.9%, ±(3% + 10 digits) |
Harmonic Distortion | - H01–H12: 99.9%, ±(5% + 10 digits)
- H13-H25A: 99.9%, ±(10% + 10 digits)
|
Inrush Current ACA | - 99.99 A, ±(3% + 0.3 A)
- 999.9 A, ±(3% + 5 digits)
|
Watts | - DC:
- 9.999 kW (10 V, 5 A minimum), ±(3% + 0.05 kW)
- 99.99 kW (10 V, 5 A minimum), ±(3% + 0.5 kW)
- 999.9 kW (10 V, 5 A minimum), ±(3% + 10 digits)
- AC:
- 9.999 kW (10 V, 5 A minimum), ±(3% + 10 digits)
- 99.99 kW (10 V, 5 A minimum), ±(3% + 10 digits)
- 999.9 kW (10 V, 5 A minimum), ±(3% + 10 digits)
|
Power Factor | -1 to 0 to 1, ±3° ±1 digit |
Resistance | - 999.9 Ω, ±(1% + 5 digits)
- 9.999 kΩ, ±(1% + 3 digits)
- 99.99 kΩ, ±(1% + 3 digits)
|
Continuity | 999.9 Ω, ±(1% + 5 digits) |
Diode | 0.4 to 0.8 V, ±0.1 V |
Capacitance | - 3.999 µF, ±(1.9% + 8 digits)
- 39.99 µF, ±(1.9% + 8 digits)
- 39.99 µF, ±(1.9% + 8 digits)
- 3.999 mF, ±(1.9% + 8 digits)
|
Measuring Rate | 3 times per second |
Meter Data |
Jaw Opening | 1.77" (45 mm) |
Bluetooth Range | 32' (10 m) |
Data Recording | Available via METERLiNK app |
Drop Test | 4' (1.2 m) |
Category Rating | CAT IV-600 V, CAT III-1000 V |
General Specifications |
Operating Ambient Temperatures and Relative Humidity | - 32 to 50°F (0 to 10°C), non-condensing
- 50 to 86°F (10 to 30°C), ≤80% RH
- 86 to 104°F (30 to 40°C), ≤75% RH
- 104 to 122°F (40 to 50°C), ≤45% RH
|
Storage Temperature and Relative Humidity | - 14 to 122°F (-10 to 50°C)
- 0 to 80% RH (batteries not fitted)
|
Temperature Coefficient | 0.2 x (specified accuracy)/°C, <18°C, >28°C |
Operating Altitude | 6562' (2000 m) |
Shock Vibration | Random vibration per MIL‐PRF‐28800f Class 2 (5 to 55 Hz, 3 g maximum) |
Pollution Degree | 2 |
Power Requirements | 6 x 1.5 V AAA alkaline batteries |
Battery Life | 50 hours with alkaline batteries (backlight, worklight, and Bluetooth off) |
Auto Power Off | Approximately 30 minutes |
Certifications | UL, CE, FCC, IC, UKCA, CSAUS |
Complies with Safety Standards | IEC 61010-1:2010, IEC 61010-2-032:2012, IEC 61010-2-033:2012 |
EMC | - FCC: 47 CFR part 15 subpart B
- CE:
- EN IEC 61326-1:2021
- EN IEC 61326-2-2:2021
- EN 301 489-1 V2.2.3 (2019-11)
- EN 301 489-17 V3.2.4 (2020-09)
- RF:
- ETSI EN 300 328 V2.2.2
- EN 62479:2010
- EN 50663:2017
|
Dimensions | 10.87 x 3.98 x 1.97" (276 x 101 x 50 mm) |
Weight | 1.43 lbs (0.65 kg), including batteries |