100g x 0.0001g w/ Automatic Internal Calibration. The AGN100 professional analytical balance offers performance, durability, and reliability. 100g capacity, resolution of 0.0001g (0.1mg), automatic calibration, 12 weighing functions, 9 units of measure, graphical display with onscreen instructions, USB, RS232, and PS2 interface ports, die-cast metal housing.
Features and Functions |
| Automatic Internal Calibration All AG scales are equipped with a state of the art automatic internal calibration mechanism. The mechanism uses a high accuracy calibration weight to calibrate the scale whenever a preset time, or temperature change initiates the process. Configuring Automatic Internal Calibration is fast and easy. In addition to having the scale calibrate automatically, calibration may be initiated at any time by the stroke of a single key. This feature is extremely important in applications which require consistently high accuracy under conditions which may allow undetected temperature changes or long periods between calibrations to affect scale accuracy. The feature is very valuable in those instances where several users share acommon scale and the calibration record can become confusing. |
| Large Graphical LCD with Backlight The AG Series is equipped with a large 5" x 3" backlit graphical LCD display, which allows the scale to display onscreen instructions and graphics. This make the PRO Series intuitive, user friendly, and easy to use. |
| Accurate and easy to use leveling system Leveling an AG scale is fast, accurate, and easy. Most AG scales use a tripod support system which consists of two adjustable legs and one fixed leg. The level sensor is a bubble type of spirit level that is omni directional. The system makes adjustment easy and very intuitive. |
| Robust die-cast metal housing The AG Series is fabricated with a rugged die cast metal housing. This makes it ideal for protecting the apparatus in tough environments. The housing provides astable weigh platform and protects the scales highly precise and delicate components. Our robust design guarantees durability and long operating life. |
| Used Capacity indicator AG scales are equipped with a used-capacity-indicator which shows the amount of the scale's capacity used during weighing. It allows the user to avoid exceeding the maximum capacity of the scale. The indicator is particularly useful in functions such as 'Totalizing" or "Compounding" where large amounts of tares are likely to be taken. In addition, AG scales have a filling indicator which is activated in the "Compounding" mode. This digital analog of an in-line meter has greatly increased sensitivity as the cutoff point is approached when filling to a preset weight. This unique feature makes compounding a much faster operation. |
| 20 Key Sealed front panel All Torbal digital scales have a sealed front panel which protects the keys and the LCD display from dust and accidental spills. With 20 logically grouped keys, the panel is simple, concise and intuitive. In addition, there are numeric keys (0-9),navigation keys, and dual (R-L) Tare keys. All keys are soft, have audible feedback,and are very responsive, which makes user interaction easy and fast. A PS-2connector on the rear of the scale allows the user with applications which require many alpha-numeric entries to use an external PC type keyboard for data entry. |
| Draft ring The draft ring is standard on all AG models with a resolution of 0.001 g(AG100, AG200, AG300, AG500). Its unique design around the pan minimizes the need for a windscreen in environments with common air movements. The draft ring provides full access to the pan while maintaining stability during weighing. |
| GLP and Data Printing This feature allows the user to print a record of a performed transaction. The printed record indicates GLP data which including the Model Number. Unit ID, User ID and a Project Number. In addition to the weighing result the receipt also contains information associated with the function in use such as, average weight time, average piece weights, reference weights, and weight limits. |
| Scanner Compatibility A Barcode Scanner can be used to quickly recall samples or limit sets from the scale's database. This feature is particularly useful in features such as parts counting or Percent weighing, where an average piece weight or a reference weight is required to carryout the transaction. To connect the barcode scanner to the scale use a PS/2 Keyboard Wedge Y-Cable Connector. |
| RS232 Interface Port A standard RS232 Port is furnished with each balance. It can be used for connecting the balance with a printer or a computer. A standard RS232communications protocol is used to send data from the scale. Data transfer can be sent automatically when a stable result is obtained, or by sending a SEND command from the computer. Under the control of Torbal™Communication Software, data may be exported to standard word processing and spreadsheet programs. |
| PS2 - External Keyboard Connection A standard PS-2 keyboard connector on the rear of the unit allows the user to use a low cost standard PC type keyboard for external alpha-numeric data entry. For those applications which require rigid test parameter recording this capability can save the user a great deal of time (and pain). |
| USB Port Every AG scale can be connected to a PC with a Standard A/B USB cable. The USB makes interfacing with a computer fast and easy. The ports bi-directional data flow allows the scale to be controlled from the PC. |
| RJ45 - Network Connection Port* (optional) This optional feature allows the scale to be networked into Laboratory Management Systems, or any other Ethernet based programs. These systems or programs require very specific structures for the bidirectional data transfers and may require some customization of the internal programin the AG scale. Please contact us for additional information regarding This feature. |
Modes |
| Weighing The scale's basic weighing function is fast, accurate and easy to use. Basic weighing operates with nine weighing units, and the function is equipped with all essential features such as the Initial Zero as well as the Automatic Zero Setting Mechanisms. The NET indicator lets the user identify that a Tare has been taken while the capacity indicator assist the user in performing weighing operations. Printed weighing results include GLP data as well as the date and time. |
| Parts Counting The AG and AGN Series incorporates one of the most versatile parts counting features available Onscreen instructions, manual and automatic operating modes make parts counting fast intuitive and accurate. When set to automatic the feature allows the user to create a database of average piece weights which are associated with parts. This minimizes an average pill counting transaction essentially to three simple steps. When using a store average piece weight the user simply selects the sample, tares the container, and counts the parts. Each average piece weight can be assigned with a unique name or a numeric barcode. The database allows you to store 100 entries which include the name of the sample and the average piece weight. When set to automatic parts counting operates in the form of a short wizard that allows the user to establish an average piece weight before each count without storing APW into a database. |
Animal Weighing Performing dynamic weighing on the AG or AGN series scales is fast and easy. The animal weighing function operates in three different modes "AUTOMATIC, SEMI-AUTOMATIC, and MANUAL." The user is allowed to select a pre- programmed time interval, or enter any desired time as it maybe required by the application. Whenever performing animal weighing the time is clearly displayed on the scale's LCD. The display also shows on screen instructions through out the entire function. |
| Check Weighing Performing check weighing on the AG or the AGN couldn't be easier. 100limit sets can be quickly assigned and recalled from the database by using the scale's numeric keypad. Each limit set can be assigned with a unique name or a numeric barcode. A weight can be quickly compared against any limit set stored in the database without restarting the transaction. In addition to displaying the weight of the object and the "ACCEPT, UNDER, OVER" Command the display indicates the difference from the target mass in percent. |
Display Hold This function is ideal for user's looking to lock weighing results on the display after weighing. The result remains locked on the display until it is cleared or removed from the pan. This function works in three operating modes "AUOTMATIC,SEMI-AUTOMATIC, AND MANUAL" which provide the user with great flexibility in using the function. |
| Percent Weighing AG and AGN Series percent weighing function allows the user to quickly establish the relative weight of an unknown compared to a stored reference weight and expressed as a percentage. The function allows to store 100reference weights each weight can be assigned with a unique name or a barcode. While performing percent weighing the display shows the difference between the mass and the reference in percent, as well as in grams. |
| Totalizing The totalizing function is ideal for summation of sequential items. The function operates in two modes (MANUAL and AUTOMATIC) and displays on screen instructions throughout the entire function. A running total can be quickly and easily viewed at any time. When viewing the totalizing report the display shows an itemized list of added weights as well as the total sum. The report can be quickly printed or transferred to a computer for further analysis. |
Check Counting Check counting allows the user to verify whether a parts counting result falls within desired limits. Just like parts counting, this function allows the user to store 100 limit sets into the scale's database. Each limit can be assigned with a unique name. The scale's graphical LCD display shows an "ACCEPT, OVER, or UNDER," result as soon as the count is finished. A parts counting result can be quickly compared against a different limit set without the need of removing the parts or restarting the transaction. |
| Compounding The compounding function has been specifically designed for recipe making and compound mixtures. This function includes features such as ingredient labeling, and a remaining to fill display which allow the user to name each ingredient and set a target weight. Combined with an onscreen non linear filling meter, these features allow the user to weigh ingredients with great precision and avoidun necessary over filling. In addition, compounded recipes can be printed. The report lists in order the name and weight of each ingredient, as well as a total weight of the recipes. This feature is designed in the form of a short wizard that displays onscreen instructions to lead the user step by step through the simple operation. |
SQC Quality Control The SQC function allows the user to set acceptable and not acceptable limits of products or articles. The function allows to store 100 of these limit sets in the scale's database. After weighing a number of preset samples in a particular batch the scale displays a trend analysis which shows where the samples fail in relation to the set limits. In addition, the user is provided with statistical data which indicates the standard and relative deviation as well as the MEAN, MIN, and MAX of the samples. |
Filtering The filtering function allows the user to perform weighing in an environment where the scale may beexposed to drafts, frequent air movements, or vibrations. Lower Modes compensate for small disturbance and high modes compensate large disturbances. |
Units | Grams, Kilograms, Carats, Pounds, Newton, Grains, Ounces, Ounces Troy, Pennyweight |