Subject to the use of all the optional accessories |
Display of results | 1 mg; 0.01% |
Weighing capacity | 40 g |
Typical reproducibility of the weighing system | Starting at an initial sample weight of approx. 1 g: +/- 0.2% Starting at an initial sample weight of approx. 5 g: +/- 0.05% |
Method of measurment | Thermogravimetric; loss on drying |
Recommended moisture range | 1.00-99.90% |
Heat source | Four parallel infrared quartz cylinders |
Temperature range and adjustment | 30-210°C in one-degree increments |
Temperature steps | Programmable; one or two |
Standby temperature | Standby temperature selectable from 30-160°C |
Temperature display | Display of target temperature and actual temperature during the measurement and in standby mode |
Display mode | Weight loss in mg|% moisture | % dry weight|% volatiles |
Modes of operation | Standard or concentration mode |
Endpoint determination | Timer mode; when value falls below a defined weight loss per time unit (%/min); trend shutoff |
Program storage | 60 programs; battery-backed memory |
Data storage | Results with statistics of the last 999 measurements: average, SD, RSD, min and max |
Adjustment of the weighing system | Manual calibration and adjustment using an external weight |
Ideal initial weight | Audio and visual display for programmable weighing of a sample to an initial target |
Initial sample weight lock | Lockable initial sample weight for optimal repeatability |
Pass-fail function | Programmable target value, including limits; pass-fail information at the end of a measurement |
Sample ID | Numeric, consecutive numbering, alphanumeric or turned off |
User management | 20 users can be stored with password protection |
Password protection | Password protection against undesired adjustment of parameters |
Languages | English, French, German, Italian, Portuguese, Spanish |
Date and time settings | dd|mm| yy, mm|dd| yy, 12 h- or 24 h-format |
Saving mode | Integrated timer to switch the analyzer on and off Programmable sleep mode after a longer period of non-use |
Display | Backlit VGA display |
Parameter and data input | Sealed membrane foil overlay with audible tactile feedback |
Real-time curves | Real-time curves of the loss in weight (% or grams) as well of the temperature curves during and after the measurement |
Acoustic signals | Key stroke, ideal weight met and end of test; selectable (on or off) |
System status indicator lights | Two tricolor LEDs (balance and heater) on front of heater module |
Data input | output | Serial and Ethernet; USB for service |
Weighing system | Monolithic weighing system for high-precision results |
Balance spill protection | Reservoir under draft shield to collect liquids, powders or granules |
Operating range | 15-30°C (59-86°F) | 10-85% rel. humidity; non-condensing |
Power requirements | 90-250 VAC 50|60 Hz, self-adjusting power supply |
Housing dimensions (W x D x H) | 41.3 x 49.5 x 23.5 cm |
Weight | 10 kg (22 lbs.), modules combined |