Operating temperature | -20°C to +60°C |
Calibration temperature | 20…28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Dimensions (HxWxD) w/ 4501 / 4511 | 109 x 23.5 x 116 / 131 mm |
Weight approx. | 155 g |
Weight incl. 4501 / 4511 (approx.) | 170 g / 255 g |
Wire size | 1 x 2.5 mm2 stranded wire |
Screw terminal torque | 0.5 Nm |
Supply voltage, universal | 21.6…253 VAC, 50…60 Hz or 19.2…300 VDC |
Max. required power | ≤ 2.5 W |
solation voltage, test / working | 2.3 kVAC / 250 VAC |
Temperature input, programmable (0…90%, 100…10%) | 1…60 s |
mA / V input (programmable) | 0.4…60 s |
2-w. supply (term. 44…43) | 25…16 VDC / 0…20 mA |
Fuse | 400 mA SB / 250 VAC |
Programming | Communication enabler 4511 / Programming front 4501 |
Signal / noise ratio | Min. 60 dB (0…100 kHz) |
Accuracy | Better than 0.1% of selected range |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE 21, A criterion, burst | < ±1% of span |
RTD type | Pt100, Ni100, lin. R |
Cable resistance per wire (max.) | 50 Ω |
Sensor current | Nom. 0.2 mA |
Sensor error detection | Yes |
Short circuit detection | < 15 Ω |
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
CJC via internally mounted sensor | < ±1.0°C |
Sensor error detection | Yes |
Sensor error current: When detecting / else | Nom. 2 μA / 0 μA |
Measurement range | 0…20 mA |
Programmable measurement ranges | 0…20 and 4…20 mA |
Input resistance | Nom. 20 Ω + PTC 50 Ω |
Measurement range | 0…12 VDC |
Programmable measurement ranges | 0/0.2…1, 0/0.5…2.5, 0/1…5, 0/2…10 VDC |
Input resistance | Nom. 10 MΩ |
Frequency output range | 0…25000 Hz |
Min. frequency (span) | 0.001 Hz |
Other output types | PNP, NPN and TTL |
Sensor error indication, programmable | 0…26250 Hz |
*of span | = of the currently selected measurement range |
MC | 2014/30/EU |
LVD | 2014/35/EU |
UL | UL 508 |
EAC | TR-CU 020/2011 |