Electrical specifications |
Environmental conditions |
Operating temperature | -20°C to +60°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications |
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Weight approx | 145 g |
Max. wire size | 1 x 2.5 mm2stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 : 2007 |
2...13.2 Hz | ±1 mm |
13.2...100 Hz | ±0.7 |
Common electrical specifications |
Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
Max. required power | ≤ 2.0 W |
Fuse | 400 mA SB / 250 VAC |
Isolation voltage - test / working | 2.3 kVAC / 250 VAC |
Communications interface | Communication enabler 4511 Programming front 4501 |
Signal / noise ratio | Min. 60 dB (0...100 kHz) |
Response time (0...90%, 100...10%) | Temperature input - ≤ 1 s mA / V input - ≤ 400 ms |
Input specifications |
RTD type | Pt10/20/50/100/200/250; Pt300/400/500/1000; Ni50/100/120/1000; Cu10/20/50/100 |
Cable resistance per wire | 50 Ω (max.) |
Sensor current | Nom. 0.2 mA |
Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
Sensor error detection | yes |
Short circuit detection | < 15 Ω |
Linear resistance min....max. | 0 Ω...10000 Ω |
Potentiometer min....max. | 10 Ω...100 kΩ |
TC input |
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
Cold junction compensation (CJC) via ext. sensor in 5910 | 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C |
CJC via int. mounted sensor | ±(2.0°C + 0.4°C * Δt) |
Δt = | internal temp.-ambient temp. |
Sensor error detection | Nom. 2 μA / 0 μA |
Current input |
Measurement range | 0...20 mA |
Programmable measurement ranges | 0...20 and 4...20 mA |
Input resistance | Nom. 20 Ω + PTC 50 Ω |
Sensor error detection: Loop break 4...20 mA | Yes |
Voltage input |
Measurement range | 0...12 VDC |
Programmable measurement ranges | 0/0.2...1, 0/1...5, 0/2...10 VDC |
Input resistance | Nom. 10 MΩ |
Current output |
Signal range | 0...20 mA |
Programmable signal ranges | 0...20/4...20/20...0/20...4 mA |
Load (@ current output) | ≤ 800 Ω |
Load stability | ≤ 0.01% of span / 100 Ω |
Sensor error indication | 0 / 3.5 / 23 mA / none |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Output limitation, on 4...20 and 20...4 mA signals | 3.8...20.5 mA |
Output limitation, on 0...20 and 20...0 mA signals | 0...20.5 mA |
Current limit | ≤ 28 mA |
Voltage output |
Signal range | 0...10 VDC |
Programmable signal ranges | 0/0.2...1; 0/1...5 ; 0/2...10; 1...0.2/0; 5...1/0; 10...2/0 V |
Load (@ voltage output) | ≥ 500 kΩ |
of span | = of the currently selected measurement rang |