IR Resolution | 320 x 240 pixels |
Display | 4 in. LCD, 320 x 240 pixels, backlit |
Object Temperature Range | –20°C to 150°C (–4°F to 302°F) 0°C to 650°C (32°F to 1202°F) |
Camera weight incl battery | 1.1 ±0.05 kg (2.4 ±0.1 lb.) |
Camera size (L x W x H) | 120 x 125 x 280 mm (4.7 x 4.9 x 11 in.) |
Contrast optimization | Digital image enhancement using FSX |
Depth of Field | 0.84 m to infinity (33 in. to infinity) |
Detector Type | Focal plane array (FPA), uncooled microbolometer |
Field of view (FOV) | 51° x 38° |
f-number | 1.25 |
Focal Length | 9 mm (0.35 in.) |
Focus | Fixed |
Image Frequency | 60 Hz |
Image Modes | TI Basic fire-fighting mode |
IR Resolution | 320 x 240 pixels |
Non-radiometric IR video recording | MPEG-4 to internal flash memory |
Non-radiometric IR video streaming | Uncompressed colorized video using USB |
Pitch | 25 µm |
Spatial resolution (IFOV) | 2.8 mrad |
Spectral Range | 7.5–13 µm |
Storage Capacity | 200 files in total, with a maximum duration of 30 minutes. The total number of files is co-dependent on the number of saved images. |
Thermal Sensitivity/NETD | <30 mK at 30°C (86°F) |
Directives | Designed to meet NFPA 1801:2013 specification: Vibration Impact acceleration resistance Corrosion Viewing surface abrasion Heat resistance Heat and flame Product label durability |
Drop | 2 m (6.6 ft.) on concrete floor (IEC 60068-2-31) |
EMC | EN 61000-6-2:2005 (Immunity) EN 61000-6-3: 2011 (Emission) FCC 47 CFR Part 15 B (Emission) |
Encapsulation | IP 67 (IEC 60529) |
Humidity (Operating and Storage) | IEC 60068-2-30/24 h 95% relative humidity 25°C to 40°C (77°F to 104°F) / 2 cycles |
Operating Temperature Range | –20°C to 85°C (–4°F to 185°F) 150°C (302°F): 15 min. 260°C (500°F): 5 min. |
Relative Humidity | 95% relative humidity 25°C to 40°C (77°F to 104°F) non-condensing. |
Shock | 25 g (IEC 60068-2-27) |
Storage Temperature Range | –40°C to 85°C (–40°F to 185°F) |
Tripod Mounting | UNC ¼"-20 (adapter needed) |
Vibration | 2 g (IEC 60068-2-6) |
Battery capacity | 4.4 Ah, at 20°C to 25°C (68°F to 77°F) |
Battery operating time | Approx. 4 hours at 25°C (77°F) ambient temperature and typical use |
Battery Type | Li Ion |
Battery voltage | 3.6 V |
Battery weight | 0.152 kg (0.3 lb.) |
Charging system | Battery is charged inside the camera 2-bay charger Optional In-truck charger |
Charging Temperature | 0°C to 45°C (32°F to 113°F) |
Charging Time | 2 h to 85% capacity, charging status indicated by LEDs |
Power Management | Automatic shutdown and sleep mode |
Start-up time from sleep mode | <4 s. |
Accuracy | ±4°C(±7.2°F) or ±4% of reading, for ambient temperature 10°C to 35°C (50°F to 95°F) |
Auto Range | Yes, selectable on/off using FLIR Tools® |
Automatic Hot Detection | Heat detection mode (the hottest 20% of the of scene is colorized) |
Languages | English |
Object Temperature Range | –20°C to 150°C (–4°F to 302°F) 0°C to 650°C (32°F to 1202°F) |
Set-up Commands | Local adaptation of units, date and time formats |