AC Current |
Range 60A | Resolution 0.01A, Accuracy ±(2.0% +8 dgts), Overload Protection 600V RMS |
Range 600A | Resolution 0.1A, Accuracy ±(2.0% +8 dgts), Overload Protection 600V RMS |
DC Current |
Range 60A | Resolution 0.01A, Accuracy ±(2.0% +8 dgts), Overload Protection 600V RMS |
Range 600A | Resolution 0.1A, Accuracy ±(2.0% +8 dgts), Overload Protection 600V RMS |
AC Volts (45Hz to 400Hz) |
Range 600mV | Resolution 0.1mV, Accuracy ± (1.0% +3 dgts), Overload Protection 750V RMS |
Range 6V | Resolution 1mV, Accuracy ± (1.0% +3 dgts), Overload Protection 750V RMS |
Range 60V | Resolution 10mV, Accuracy ± (1.0% +3 dgts), Overload Protection 750V RMS |
Range 600V | Resolution 100mV, Accuracy ± (1.0% +3 dgts), Overload Protection 750V RMS |
Range 750V | Resolution 1.0V, Accuracy ± (1.0% +3 dgts), Overload Protection 750V RMS |
DC Volts |
Range 600mV | Resolution 0.1mV, Accuracy ± (0.5% +4 dgts), Overload Protection 1000V RMS |
Range 6V | Resolution 1mV, Accuracy ± (0.5% +4 dgts), Overload Protection 1000V RMS |
Range 60V | Resolution 10mV, Accuracy ± (0.5% +4 dgts), Overload Protection 1000V RMS |
Range 600V | Resolution 1000mV, Accuracy ± (0.5% +4 dgts), Overload Protection 1000V RMS |
Range 1000V | Resolution 1V, Accuracy ± (0.8% +5 dgts), Overload Protection 1000V RMS |
DC Low Amps |
Range 600µA | Resolution 0.1µA, Accuracy - ± (1.2% +3 dgts), Overload Protection 2000µA/600V RMS |
Range 2000µA | Resolution 1µA, Accuracy ± (1.2% +3 dgts), Overload Protection 2000µA/600V RMS |
AC Low Amps |
Range 600µA | Resolution - 0.1µA, Accuracy ± (1.2% +3 dgts), Overload Protection 2000µA/600V RMS |
Range 2000µA | Resolution 1µA, Accuracy ± (1.2% +3 dgts), Overload Protection 2000µA/600V RMS |
Resistance |
Range 600Ω | Resolution 0.1Ω, Accuracy ± (0.8% +3 dgts), Overload Protection 600V RMS |
Range 6kΩ | Resolution 1Ω, Accuracy ± (0.8% +3 dgts), Overload Protection 600V RMS |
Range 60kΩ | Resolution 10Ω, Accuracy ± (0.8% +3 dgts), Overload Protection 600V RMS |
Range 600kΩ | Resolution 100Ω, Accuracy ± (0.8% +3 dgts), Overload Protection 600V RMS |
Range 6MΩ | Resolution 1kΩ, Accuracy ± (0.8% +3 dgts), Overload Protection 600V RMS |
Range 60MΩ | Resolution 01MΩ, Accuracy ± (1.2% +3 dgts), Overload Protection 600V RMS |
Frequency |
Range 99.99Hz | Resolution 0.01Hz, Accuracy ± (0.1% +3 dgts), Overload Protection 600V RMS |
Range 999.9Hz | Resolution 0.1Hz, Accuracy ± (0.1% +3 dgts), Overload Protection 600V RMS |
Range 9.999kHz | Resolution 1Hz, Accuracy ± (0.1% +3 dgts), Overload Protection 600V RMS |
Range 99.99kHz | Resolution 10Hz, Accuracy ± (0.1% +3 dgts), Overload Protection 600V RMS |
Duty Cycle |
Range 1.0 to 99% | Accuracy ±(0.2% per kHz + 0.1% + 5dgts), Overload Protection - 600V RMS |
Diode Test |
Range 3.0V | Open Circuit V <3.2V DC, Test Current 0.25mA, Overload Protection 600V RMS |
Capacitance |
Range 10.00nF | Resolution 0.01nF, Accuracy ± (3.0% +5 dgts), Overload Protection 600V RMS |
Range 100.0nF | Resolution 0.1nF, Accuracy ± (3.0% +5 dgts), Overload Protection 600V RMS |
Range 1.000µF | Resolution 0.001µF, Accuracy ± (3.0% +5 dgts), Overload Protection 600V RMS |
Range 10.00µF | Resolution 0.01µF, Accuracy ± (3.0% +5 dgts), Overload Protection 600V RMS |
Range 100.0µF | Resolution 0.1µF, Accuracy ± (3.0% +5 dgts), Overload Protection 600V RMS |
Range 2000µF | Resolution 1µF, Accuracy ± (3.0% +5 dgts), Overload Protection 600V RMS |
Continuity |
Open Circuit V <1.00V | Threshold Appox. <40Ω, Overload Protection 600V RMS |
Temperature |
Range -328F to 999F (-200 to 999C) | Resolution 0.1°F (0.1C), Accuracy ±(1.0% +3.6F) ±(1.0% + 2.0C), Overload Protection 30V RMS |
Range 1000F to 2462F (1000 to 1350C) | Resolution 0.1°F (0.1C), Accuracy ±(1.0% +3.0F) ±(1.0% + 2.0C), Overload Protection 30V RMS |