Load Cell Excitation | 3.0 VDC at 87.5Ω, 4.6 VDC at 700Ω |
Load Cell Current | 34mA (4 x 350Ω load cells) or (8 x 700Ω load cells) |
Load Cell Cabling | Four and six-wire with remote sensing (recommended) |
Analog Signal Input Range | 0.6mV/V - 4.0mV/V |
Analog Signal Sensitivity | 0.2 µV/graduation minimum, 1.5 µV/graduation recommended |
Conversion Rate | 60 updates/second |
Resolution | 10,000 displayed graduations (NTEP Certified), 1,000,000 expanded The maximum number of allowed graduations will vary by application |
Display Increments | 38354 |
Display | Seven-digit, seven-segment LCD display 121 x 24 dot matrix messaging area with white LED backlight |
Decimal Point | Configurable with dead zeros |
Unit Switching | Configurable for two units of measurement with front panel operation with conversion for tare and setpoint values |
Front Panel Control Switches | Zero, Gross/Net, Tare, Print, Units Conv, Start, Stop, Full numeric keypad |
Front Panel | Ten-button plus power button flat membrane panel |
Front Panel Annunciators | Center Zero, Gross, Net, Motion, lb, kg, oz, g |
Motion Band | Configurable to ± 1 or ± 3 graduations, 1 second delay (or Off) |
Power Input | 5.8-7.9 VDC,100-175mA Maximum power consumption 0.25 watts |
Operating Temperature | 14° F to 104° F (-10°C to 40°C) legal |
Electrical Operating Temperature | 14° F to 104° F (-10°C to 40°C) legal |
Rating/Material | Stainless steel IP66 enclosure |
Weight | 6.1 lb (2.8 kg) |